Guide

Wastewater aeration glossary

Short answer

Short, plain definitions of the terms that come up when sizing or buying aeration for a wastewater treatment plant in Ireland.

Last updated

Treatment terms

  • BOD (biochemical oxygen demand): The oxygen bacteria use to break down the organic matter in wastewater over five days, in mg/L. The main measure of organic load and a common licence limit.
  • COD (chemical oxygen demand): The oxygen needed to oxidise everything in the sample chemically. Quicker to measure than BOD and always higher.
  • Dissolved oxygen (DO): Oxygen dissolved in the water and available to bacteria, in mg/L. Most aeration tanks are run at about 1.5 to 2 mg/L.
  • Activated sludge: A treatment process where wastewater is aerated with a mass of bacteria (the sludge) that eats the organic matter, then settled and partly returned.
  • MLSS (mixed liquor suspended solids): The concentration of solids, mostly bacteria, in an aeration tank, in mg/L. Aeration must keep them in suspension.
  • Nitrification: The bacterial conversion of ammonia to nitrate, which needs enough dissolved oxygen and slows sharply when DO is low.
  • Anoxic zone: A mixed but not aerated part of a tank, with no dissolved oxygen, used to remove nitrate (denitrification).
  • Oxidation ditch: A looped channel where wastewater circulates and is aerated, often by surface aerators or rotors.
  • Balancing tank: A tank that stores incoming wastewater to even out flow and load before treatment. Usually mixed, often aerated to stay fresh.
  • Sludge holding tank: A tank that stores sludge before removal. Aerating it keeps it from going septic and limits odour.

Aeration performance terms

  • AOR (actual oxygen requirement): The oxygen the plant needs each day in real conditions, worked out from the BOD and ammonia load, in kg O2 per day.
  • SOTR (standard oxygen transfer rate): The oxygen an aerator transfers per hour in clean water at standard test conditions, in kg O2 per hour.
  • SAE (standard aeration efficiency): Oxygen transferred per unit of power in clean water at standard conditions, in kg O2 per kWh. Used to compare aerators.
  • Alpha factor: The ratio of oxygen transfer in wastewater to transfer in clean water. Below 1, so field transfer is lower than the brochure figure.
  • Field transfer: The oxygen an aerator actually delivers in your wastewater, temperature and DO set point, often 50 to 70 percent of the clean water figure for surface aerators.
  • Mixing power (W per m3): Installed power per cubic metre of tank, used to check the tank stays mixed. About 1 to 2 W per m3 for partial mixing and 5 to 8 W per m3 to keep all solids suspended.

Equipment terms

  • Floating surface aerator: A motor driven unit on a float that churns or throws water into the air so oxygen dissolves. Moored in the tank and rises and falls with the level.
  • High speed surface aerator: A direct drive surface aerator (roughly 750 to 1,800 rpm). Lower cost and usually floating.
  • Low speed surface aerator: A large turbine turned slowly through a gearbox. Moves more water per kW; fixed or float mounted.
  • Aspirating aerator mixer: A propeller that draws air down a hollow shaft and drives it into the water, aerating and mixing in one unit.
  • Draft tube: A tube under a surface aerator that draws water from near the floor, so the whole depth of the tank is mixed.
  • Fine bubble diffuser: A membrane or ceramic disc or tube on the tank floor that releases small air bubbles from a blower. Efficient, but the tank must be emptied to install or repair.
  • Mooring: The cables and fixings that hold a floating aerator in position, to the tank walls or to anchors on the bank.

Licensing terms in Ireland

  • Agglomeration: A town or area whose wastewater is collected to one treatment plant. The unit the EPA licenses and reports on for public wastewater.
  • Wastewater discharge licence: The EPA authorisation for a public wastewater discharge under the Waste Water Discharge (Authorisation) Regulations 2007, with emission limit values.
  • IE licence (industrial emissions): The EPA licence for larger industrial activities, including food, drink and dairy processing, which sets limits on emissions to water.
  • Section 4 licence: A local authority licence under section 4 of the Water Pollution Acts for a trade or sewage discharge to waters not covered by an EPA licence.
  • ELV (emission limit value): A limit in a licence on what the treated effluent may contain, such as BOD, suspended solids, ammonia or phosphorus.

Sized for your tank

Send the tank size, depth and what flows in. We reply with questions or a written proposal.

Send an enquiry

Send an enquiry

New units, supplied and installed across Ireland. Sold by enquiry.

  1. Tell us about the tankSize, depth, what flows in and what your licence asks for. A rough figure is enough to start.
  2. Sizing and proposalA written proposal with unit sizes, the working behind them and the running cost.
  3. Supply and installUnits go into the working tank on anchored moorings. No emptying, no concrete works.
  4. Handover and warrantyWe commission the units with you and hand over the manufacturer warranty and documents.

Or call 087 473 6464 or email [email protected]

We use your details only to reply. No cookies, no mailing list.

Send an enquiryCall