What dissolved oxygen level should an aeration tank hold?

Short answer

Most activated sludge aeration tanks are run at about 1.5 to 2 mg/L of dissolved oxygen. Much below 1 mg/L, treatment slows and nitrification (ammonia removal) can stop; well above about 2.5 mg/L, extra aeration mostly wastes energy without improving treatment.

Last updated

Why does dissolved oxygen matter?

The bacteria that remove BOD and ammonia need oxygen. Dissolved oxygen (DO) is the oxygen actually available to them in the water, measured in mg/L. It is the simplest daily check that aeration is keeping up with the load.

What happens when DO is too low?

  • Ammonia removal slows sharply and can stop below about 0.5 mg/L
  • BOD removal slows, so effluent quality drops
  • The tank can turn septic, with odour and poor settling
  • Filamentous bacteria can grow and cause bulking sludge

What happens when DO is too high?

Holding DO well above what the process needs uses more power for little or no gain. Aeration is usually the largest energy use at a treatment plant, so running at the right level saves money.

How do aerators control DO?

With a DO probe in the tank, floating aerators can be switched by timer, by DO set points, or run at variable speed, so oxygen follows the load through the day. Placing units to cover the whole tank avoids low DO corners.

Sources

US Department of Energy, Better Plants training: Aeration Systems (bptraining.ornl.gov). Typical ranges vary with the process; follow your plant's design and licence.

Sized for your tank

Send the tank size, depth and what flows in. We reply with questions or a written proposal.

Send an enquiry

Frequently asked questions

What is a normal DO reading in an aeration tank?

About 1.5 to 2 mg/L for most activated sludge tanks. Check your plant's design figure.

Can a floating aerator raise DO in an existing tank?

Yes. A floating aerator adds oxygen to the working tank and can be sized to make up the shortfall between the oxygen the load needs and what the existing system delivers.

Send an enquiry

New units, supplied and installed across Ireland. Sold by enquiry.

  1. Tell us about the tankSize, depth, what flows in and what your licence asks for. A rough figure is enough to start.
  2. Sizing and proposalA written proposal with unit sizes, the working behind them and the running cost.
  3. Supply and installUnits go into the working tank on anchored moorings. No emptying, no concrete works.
  4. Handover and warrantyWe commission the units with you and hand over the manufacturer warranty and documents.

Or call 087 473 6464 or email [email protected]

We use your details only to reply. No cookies, no mailing list.

Send an enquiryCall