Guide

Is your wastewater plant failing its licence? Start with aeration

Short answer

The EPA reported in October 2025 that 59 percent of licensed urban wastewater treatment plants in Ireland failed to consistently meet the standards in their licences in 2024, and that nearly half of those failures came from poor operation rather than missing infrastructure. Too little oxygen or poor mixing in the biological stage is one of the operational causes that can be checked and fixed without rebuilding the plant.

Last updated

What did the EPA find?

  • 59 percent of licensed plants failed to consistently meet their licence standards in 2024
  • Nearly half of those failures were put down to poor operational management
  • 14 large towns and cities failed Urban Wastewater Treatment Directive standards
  • Uisce Éireann had not started the needed works at half of 78 priority areas
  • The EPA has prosecuted Uisce Éireann 28 times for failing to treat wastewater properly

How do I know if aeration is the problem?

Biological treatment depends on bacteria that need dissolved oxygen. Signs that a tank is short of oxygen or poorly mixed:

  • Dissolved oxygen in the aeration tank regularly below about 1 mg/L
  • Ammonia or BOD results creeping towards the emission limit values
  • Odour, dark or grey liquor, or rising sludge
  • Dead zones where solids settle and the surface is still
  • Results that get worse when the load rises, for example in summer or at production peaks
  • Failed or blocked diffusers, or a blower running flat out

What can be done without rebuilding the plant?

Floating aerators and aerator mixers go into the working tank on moorings, so treatment carries on. They can top up oxygen where the existing system is short, take over while diffusers are repaired, or break up dead zones. Each job is sized from the load and the tank, and the working is shown.

Aeration is only one part of a plant. If screening, settling, sludge removal or control are the issue, more oxygen will not fix it, and we will say so.

What should I send with an enquiry?

  • Tank sizes and depths
  • Flow and load, including peaks
  • Recent monitoring results and dissolved oxygen readings
  • The emission limits in the licence
  • What aeration is there now and its condition

Sources

EPA, Urban Wastewater Treatment in 2024 and news release of 9 October 2025 (epa.ie). This guide is general information, not legal or compliance advice.

Sized for your tank

Send the tank size, depth and what flows in. We reply with questions or a written proposal.

Send an enquiry

Frequently asked questions

Why do so many Irish wastewater plants fail their licence?

The EPA puts it down to two things: inadequate infrastructure, and poor operation and maintenance of existing plants. Nearly half of the licence failures it found for 2024 came from operational management.

Can adding aeration help a plant meet its licence?

Where the biological stage is short of oxygen or poorly mixed, yes. Enough dissolved oxygen is needed to remove BOD and ammonia. It will not fix problems in other parts of the plant.

Send an enquiry

New units, supplied and installed across Ireland. Sold by enquiry.

  1. Tell us about the tankSize, depth, what flows in and what your licence asks for. A rough figure is enough to start.
  2. Sizing and proposalA written proposal with unit sizes, the working behind them and the running cost.
  3. Supply and installUnits go into the working tank on anchored moorings. No emptying, no concrete works.
  4. Handover and warrantyWe commission the units with you and hand over the manufacturer warranty and documents.

Or call 087 473 6464 or email [email protected]

We use your details only to reply. No cookies, no mailing list.

Send an enquiryCall